Gardnerella Vaginalis Nucleic Acid

Short Description:

This kit is suitable for the qualitative detection of Gardnerella vaginalis nucleic acid in male urethral swabs, female cervical swabs, and female vaginal swab samples.


Product Detail

Product Tags

Product name

HWTS-UR042-Gardnerella Vaginalis Nucleic Acid Detection Kit(Fluorescence PCR)

Epidemiology

The most common cause of vaginitis in women is bacterial vaginosis, and the important pathogenic bacterium of bacterial vaginosis is Gardnerella vaginalis. Gardnerella vaginalis (GV) is an opportunistic pathogen that does not cause disease when present in small amounts. However, when the dominant vaginal bacteria Lactobacilli are reduced or eliminated, causing an imbalance in the vaginal environment, Gardnerella vaginalis multiplies in large numbers, leading to bacterial vaginosis. At the same time, other pathogens (such as Candida, Neisseria gonorrhoeae, Chlamydia trachomatis, etc.) are more likely to invade the human body, causing mixed vaginitis and cervicitis. If vaginitis and cervicitis are not diagnosed and treated in a timely and effective manner, there may be ascending infections by the pathogens along the reproductive tract mucosa, easily leading to upper reproductive tract infections such as endometritis, salpingitis, tubo-ovarian abscess (TOA), and pelvic peritonitis, which may lead to serious complications such as infertility, ectopic pregnancy and even adverse pregnancy outcomes.

Technical Parameters

Storage

-18℃

Shelf-life 12 months
Specimen Type male urethral swabs, female cervical swabs,female vaginal swab
Ct ≤38
CV <5.0%
LoD 400 Copies/mL
Applicable Instruments Applicable to type I detection reagent: Applied Biosystems 7500 Real-Time PCR Systems,

QuantStudio®5 Real-Time PCR Systems, 

SLAN-96P Real-Time PCR Systems (Hongshi Medical Technology Co., Ltd.),

LineGene 9600 Plus Real-Time PCR Detection Systems (FQD-96A, Hangzhou Bioer technology), 

MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.),

BioRad CFX96 Real-Time PCR System,

BioRad CFX Opus 96 Real-Time PCR System.

Applicable to type II detection reagent:

EudemonTM AIO800 (HWTS-EQ007) by Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Work Flow

Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (which can be used with Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)), and Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-8) (which can be used with EudemonTM AIO800 (HWTS-EQ007)) by Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

The extracted sample volume is 200μL and the recommended elution volume is 150μL.