Herpes simplex virus type 1/2, Trichomonal vaginitis nucleic acid

Short Description:

The kit is intended for the in vitro qualitative detection of Herpes Simplex Virus Type 1 (HSV1), Herpes Simplex Virus Type 2 (HSV2), and Trichomonal vaginitis (TV) in male urethral swab, female cervical swab, and female vaginal swab samples, and provide aid to the diagnosis and treatment of patients with genitourinary tract infections.


Product Detail

Product Tags

Product name

HWTS-UR045-Herpes simplex virus type 1/2, Trichomonal vaginitis nucleic acid detection kit (Fluorescence PCR)

Epidemiology

Genital herpes is a common sexually transmitted disease caused by HSV2, which is highly infectious. In recent years, the incidence of genital herpes has increased significantly, and due to an increase in risky sexual behaviors, the detection rate for HSV1 in genital herpes has increased and was reported to be as high as 20%-30%. An initial infection with the genital herpes virus is mostly silent without obvious clinical symptoms except local herpes in the mucosa or skin of a few patients. Since genital herpes is characterized by lifelong viral shedding and proneness towards recurrence, it is important to screen the pathogens as soon as possible and block its transmission.

Technical Parameters

Storage

-18℃

Shelf-life 12 months
Specimen Type male urethral swab,female cervical swab,female vaginal swab
Ct ≤38
CV <5.0%
LoD 400 Copies/mL
Applicable Instruments Applicable to type I detection reagent:

Applied Biosystems 7500 Real-Time PCR Systems, 

QuantStudio®5 Real-Time PCR Systems, 

SLAN-96P Real-Time PCR Systems (Hongshi Medical Technology Co., Ltd.),

LineGene 9600 Plus Real-Time PCR Detection Systems (FQD-96A, Hangzhou Bioer technology), 

MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.),

BioRad CFX96 Real-Time PCR System,

BioRad CFX Opus 96 Real-Time PCR System.

Applicable to type II detection reagent:

EudemonTM AIO800 (HWTS-EQ007) by Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Work Flow

Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (which can be used with Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)), and Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-8) (which can be used with EudemonTM AIO800 (HWTS-EQ007)) by Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

The extracted sample volume is 200μL and the recommended elution volume is 150μL.


  • Previous:
  • Next:

  • Write your message here and send it to us