Low price for Malaria Nucleic Acid Detection Kit – Plasmodium Falciparum Antigen Detection Kit (Colloidal Gold) – Macro & Micro-Test
Low price for Malaria Nucleic Acid Detection Kit – Plasmodium Falciparum Antigen Detection Kit (Colloidal Gold) – Macro & Micro-Test Detail:
Product name
Plasmodium Falciparum Antigen Detection Kit (Colloidal Gold )
Certificate
CE
Epidemiology
Malaria (Mal) is caused by Plasmodium, which is a single-celled eukaryotic organism, including Plasmodium falciparum, Plasmodium vivax, Plasmodium malariae, and Plasmodium ovale. It is a mosquito-borne and blood-borne parasitic disease that seriously threatens human health. Of the parasites that cause malaria in humans, Plasmodium falciparum is the deadliest. Malaria is distributed worldwide, mainly in tropical and subtropical regions such as Africa, Central America, and South America.
Features
● Rapid: Read results in 15 minutes.
● Easy to use: Only 3 steps.
● Convenient: No instrument.
● Room temperature: Transportation & storage at 4-30℃ for 24 months.
● Accuracy: High sensitivity & specificity.
Technical Parameters
Target region | Plasmodium falciparum |
Storage temperature | 4-30 ℃ sealed dry storage |
Sample type | human peripheral blood and venous blood |
Shelf life | 24 months |
Auxiliary instruments | Not required |
Extra Consumables | Not required |
Detection time | 15-20 mins |
Specificity | There is no cross-reactivity with influenza A H1N1 virus, H3N2 influenza virus, influenza B virus, dengue fever virus, Japanese encephalitis virus, respiratory syncytial virus, meningococcus, parainfluenza virus, rhinovirus, toxic bacillary dysentery, There was no crossover between Staphylococcus aureus, Escherichia coli, Streptococcus pneumoniae or Klebsiella pneumoniae, Salmonella typhi, and Rickettsia tsutsugamushi. |
Work Flow
1. Sampling
● Clean the fingertip with an alcohol pad.
● Squeeze the end of the fingertip and pierce it with the provided lancet.
2. Add the sample and solution
● Add 1 drop of sample to the “S” well of the cassette.
● Hold the buffer bottle vertically, and drop 3 drops (about 100 μL) into the “A” well.
3. Read the result (15-20mins)
Precautions:
1. Do not read the result after 20 mins.
2. After opening, please use the product within 1 hour.
3. Please add samples and buffers in strict accordance with the instructions.
Main Components
Catalogue Number |
Packaging Size | Components | Specification | Quantity |
HWTS-OT056A |
1 test/kit |
Test Cassette | 1pc/bag | 1 bag |
Sample Extraction Solution | 0.2mL/bottle | 1 bottle | ||
Lancet | 1pc/bag | 1 bag | ||
Pipette | 1pc/bag | 1 bag | ||
HWTS-OT056B |
20 tests/kit |
Test Cassette | 1pc/bag | 20 bags |
Sample Extraction Solution | 4mL/bottle | 1 bottle | ||
Lancet | 20pcs/bag | 1 bag | ||
Pipette | 20pcs/bag | 1 bag |
Product detail pictures:






Related Product Guide:
The company upholds the philosophy of Be No.1 in quality, be rooted on credit and trustworthiness for growth, will continue to serve old and new customers from home and overseas whole-heatedly for Low price for Malaria Nucleic Acid Detection Kit – Plasmodium Falciparum Antigen Detection Kit (Colloidal Gold) – Macro & Micro-Test , The product will supply to all over the world, such as: Tajikistan, Yemen, Belize, With the first-class solutions, excellent service, fast delivery and the best price, we've won highly praise foreign customers'. Our products have been exported to Africa, the Middle East, Southeast Asia and other regions.