China wholesale Vibrio Cholerae O1 And Enterotoxin Gene Nucleic Acid Detection Kit (Fluorescence Pcr) - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We stick to the principle of quality first, service first, continuous improvement and innovation to meet the customers for the management and zero defect, zero complaints as the quality objective. To perfect our service, we provide the products with the good quality at the reasonable price for Denv Nucleic Acid, Adenovirus And Adenovirus Type 41, Rotavirus And Adenovirus Antigen, We sincerely count on exchange and cooperation with you. Allow us to move ahead hand in hand and attain win-win situation.
China wholesale Vibrio Cholerae O1 And Enterotoxin Gene Nucleic Acid Detection Kit (Fluorescence Pcr) - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test Detail:

Product name

Macro & Micro-Test Sample Release Reagent

Certificate

CE, FDA, NMPA

Features

Rapid: only 5 mins.

Easy: only 3 steps (1.add the sample 2.Mix upside and down 10 times 3. Leave it for 5 mins).

Main components

Name Main components Component specifications Quantity
Sample Release reagent Dithiothreitol, sodium dodecyl sulfate (SDS), RNase inhibitor, surfactant, purified water 0.5mL/Vial 50 Vial

Note: Components in different batches of kits are not interchangeable.

Storage conditions and shelf life

Store and transport at room temperature. The shelf life is 24 months. 

Applicable instruments

Instruments and equipment during sample processing, such as pipettes, vortex mixers, water baths, etc. 

Sample requirements

Freshly collected oropharyngeal swabs, nasopharyngeal swabs.

Precision

When this kit is used for extraction from the in-house precision reference CV for 10 replicates, the coefficient of variation (CV, %) of Ct value is not more than 10%.

Inter-batch difference

When the in-house precision reference is tested on three batches of kits under trial production upon repeated extraction and, the coefficient of variation (CV, %) of Ct value is not more than 10%.

Performance comparison

● Extraction efficiency comparsion

Efficiency comparsion of magnetic beads method and sample releaser

concentration
copies/mL

magnetic beads method

sample releaser

orfab

N

orfab

N

20000

28.01

28.76

28.6

29.15

2000

31.53

31.9

32.35

32.37

500

33.8

34

35.25

35.9

200

35.25

35.9

35.83

35.96

100

36.99

37.7

38.13

undet

The extraction efficiency of sample releaser was similar to that of magnetic beads method, and the concentration of pathogen could be 200Copies/mL.

● CV value comparison

Repeatability of sample releaser extraction

concentration:5000Copies/mL

ORF1ab

N

30.17

30.38

30.09

30.36

30.36

30.26

30.03

30.48

30.14

30.45

30.31

30.16

30.38

30.7

30.72

30.79

CV

0.73%

0.69%

When tested at 5,000 copies /mL, the CV of orFab and N was 0.73% and 0.69%, respectively.

Macro & Micro-Test Sample Release Reagent10


Product detail pictures:

China wholesale Vibrio Cholerae O1 And Enterotoxin Gene Nucleic Acid Detection Kit (Fluorescence Pcr) - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test detail pictures

China wholesale Vibrio Cholerae O1 And Enterotoxin Gene Nucleic Acid Detection Kit (Fluorescence Pcr) - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test detail pictures

China wholesale Vibrio Cholerae O1 And Enterotoxin Gene Nucleic Acid Detection Kit (Fluorescence Pcr) - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test detail pictures

China wholesale Vibrio Cholerae O1 And Enterotoxin Gene Nucleic Acid Detection Kit (Fluorescence Pcr) - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test detail pictures

China wholesale Vibrio Cholerae O1 And Enterotoxin Gene Nucleic Acid Detection Kit (Fluorescence Pcr) - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test detail pictures


Related Product Guide:

Our commission would be to serve our customers and clientele with very best excellent and aggressive portable digital products for China wholesale Vibrio Cholerae O1 And Enterotoxin Gene Nucleic Acid Detection Kit (Fluorescence Pcr) - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test , The product will supply to all over the world, such as: Swiss, Doha, Ethiopia, The president and all the company members would like to provide qualified goods and services for customers and sincerely welcome and cooperate with all native and foreign customers for a bright future.
  • Company director has very rich management experience and strict attitude, sales staff are warm and cheerful, technical staff are professional and responsible,so we have no worry about product,a nice manufacturer.
    5 Stars By Jason from Palestine - 2017.05.21 12:31
    Superb technology, perfect after-sales service and efficient work efficiency, we think this is our best choice.
    5 Stars By Roland Jacka from Swaziland - 2017.11.12 12:31
    Write your message here and send it to us