PriceList for Hpv 16 And 18 - 14 High-Risk HPV with 16/18 Genotyping Test Kit (Fluorescence PCR) – Macro & Micro-Test
PriceList for Hpv 16 And 18 - 14 High-Risk HPV with 16/18 Genotyping Test Kit (Fluorescence PCR) – Macro & Micro-Test Detail:
Product name
14 High-Risk HPV with 16/18 Genotyping Test Kit (Fluorescence PCR)
Freeze-dried 14 Types of High-risk Human Papilloma Virus (16/18 Typing) Nucleic Acid Detection Kit (Fluorescence PCR)
Certificate
CE
Epidemiology
Cervical cancer is one of the most common malignant tumors in the female reproductive tract. It has been shown that persistent HPV infection and multiple infections are one of major causes of cervical cancer. Currently there is still a lack of generally accepted effective treatments for cervical cancer caused by HPV. Therefore, early detection and prevention of cervical infection caused by HPV are the keys to prevention of cervical cancerization. Establishment of simple, specific and rapid diagnostic tests for pathogens is of great significance for clinical diagnosis of cervical cancer.
Features
● Multiplex PCR Amplification Technology
● Internal control: Fully monitor the experimental process to ensure the quality of Experiments.
● High sensitivity: 25 Copies/reaction
● High specificity: No cross-reactivity with common respiratory pathogens for more accurate results.
● Convenient: One test for multiple results
Channel
| Channel | Type |
| FAM | HPV 18 |
| VIC/HEX | HPV 16 |
| ROX | HPV 31, 33, 35, 39, 45,51,52, 56, 58, 59, 66, 68 |
| CY5 | Internal Control |
PCR Amplification Conditions Setting
| Step | Cycles | Temperature | Time | Collect Fluorescent Signals or Not |
| 1 | 1 cycle | 50℃ | 2mins | No |
| 2 | 1 cycle | 95℃ | 10mins | No |
| 3 | 10 cycles | 95℃ | 15 s | No |
| 62℃ | 20 s | No | ||
| 4 | 30 cycles | 95℃ | 15 s | No |
| 58℃ | 30 s | Yes |
Technical Parameters
| Storage | ≤-18℃ in dark |
| Shelf-life | 12 months |
| Specimen Type | Cervical exfoliated cells |
| Ct | ≤28 |
| CV | ≤5.0% |
| LoD | Liquid |
| Specificity | No cross-reactivity with common reproductive tract pathogens (such as ureaplasma urealyticum, genital tract chlamydia trachomatis, candida albicans, neisseria gonorrhoeae, trichomonas vaginalis, mold, gardnerella and other HPV types not covered in the kit, etc). |
| Applicable Instruments | It can match the mainstream fluorescent PCR instruments on the market. |
| SLAN-96P Real-Time PCR Systems | |
| ABI 7500 Real-Time PCR Systems | |
| QuantStudio®5 Real-Time PCR Systems | |
| LightCycler®480 Real-Time PCR Systems | |
| LineGene 9600 Plus Real-Time PCR Detection Systems | |
| MA-6000 Real-Time Quantitative Thermal Cycle | |
Main Components
14 High-Risk HPV with 16/18 Genotyping Test Kit (Fluorescence PCR)
| Catalogue Number | Component (50 tests/kit) | Specification | Quantity | Component Description |
| HWTS-CC007A | HPV Reaction Buffer | 950μL/vial | 1 vial | Amplification reagents |
| HPV Primer and Probe Mix | 300μL/vial | 1 vial | Mix of various types of primers and probes | |
| HPV Positive Control | 600μL/vial | 1 vial | Mix of HPV 16, 18, 33 and internal control Templates | |
| HPV Blank Control | 600μL/vial | 1 vial | DNase/RNase free H2O |
Freeze-dried 14 Types of High-risk Human Papilloma Virus (16/18 Typing) Nucleic Acid Detection Kit (Fluorescence PCR)
| Component | Character | Catalogue Number | Component Description | |
| HWTS-CC010A | HWTS-CC010B | |||
| Specification/Quantity (20 tests/kit) |
Specification/Quantity (50 tests/kit) |
|||
| HPV Reaction Buffer | Lyophilization | 1 bottle | 1 bottle | Amplification reaction reagents and kinds of primers, probes |
| HPV Positive Control | Lyophilization | 1 vial | 1 vial | Mixture of HPV16, 18, 33 and their internal control plasmids |
| HPV Blank Control | Liquid | 1 vial, 600μL/vial | 1 vial, 600μL/vial | DNase/RNase free H2O |
| Reconstituted Solution | Liquid | 1 vial, 1mL/vial | 1 vial, 1.45mL/vial | DNase/RNase free H2O, etc. |
Total PCR Solution
Option 1.

Option 2.

References
1. Guo Yumei, Sun Jie, Chen Yadan, et al. HPV testing and its significance in the diagnosis of cervical cancer [J]. Chinese Journal of Laboratory Diagnosis, 2009,13: 1306-1308.
2. Li Hua, Gao Guolan. Advance in research on HPV and cervical cancer [J]. The Practical Journal of Cancer, 2007, 22: 420-422.
3. He Guishan. Advance in research on HPV detection methods [J]. Gansu Medical Journal, 2009, 28: 182-183.
4. Ning Tang, Shihai Huang, Brian Erickson, et al. High-risk HPV detection and concurrent HPV 16 and 18 typing with abbott realtime high risk HPV test [J]. Journal of Clinical Virology, 2009, 45: S25-S28.
Product detail pictures:
Related Product Guide:
We keep on with the theory of quality first, provider initially, constant improvement and innovation to meet the customers with the management and zero defect, zero complaints as the standard objective. To great our company, we deliver the merchandise using the fantastic excellent at the reasonable price for PriceList for Hpv 16 And 18 - 14 High-Risk HPV with 16/18 Genotyping Test Kit (Fluorescence PCR) – Macro & Micro-Test , The product will supply to all over the world, such as: Sweden, South Africa, Haiti, Our products are widely sold to Europe, USA, Russia, UK, France, Australia, Middle East, South America, Africa, and Southeast Asia, etc. Our products are highly recognized by our customers from all around the world. And our company is committed to continually improving effectiveness of our management system to maximize customer satisfaction. We sincerely hope to make progress with our customers and create a win-win future together. Welcome to join us for business!
Managers are visionary, they have the idea of mutual benefits, continuous improvement and innovation, we have a pleasant conversation and Cooperation.


