OEM/ODM Manufacturer Hpv 16 18 - 18 Types of High-risk Human Papilloma Virus Nucleic Acid Detection Kit – Macro & Micro-Test

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We also offer product sourcing and flight consolidation services. We have our own factory and sourcing office. We can provide you with almost every type of product related to our product range for Malaria Nucleic Acid Detection Kit, Hepatitis B Molecular Test, Hpv Genotyping Pcr, We value your inquiry, For more details, please contact us, we will reply you ASAP!
OEM/ODM Manufacturer Hpv 16 18 - 18 Types of High-risk Human Papilloma Virus Nucleic Acid Detection Kit – Macro & Micro-Test Detail:

Product name

18 Types of High-risk Human Papilloma Virus Nucleic Acid Detection Kit (Fluorescence PCR)

Certificate

CE

Epidemiology

Cervical cancer is one of the most common malignant tumors in the female reproductive tract. Studies have shown that persistent infection and multiple infections of human papillomavirus are one of the important causes of cervical cancer.

Reproductive tract HPV infection is common among women with sexual life. According to statistics, 70% to 80% of women may have HPV infection for once at least in their lifetime, but most infections are self-limiting, and more than 90% of infected women will develop an effective immune response that could clear the infection between 6 and 24 months without any long-term health intervention. Persistent high-risk HPV infection is the main cause of cervical intraepithelial neoplasia and cervical cancer.

The worldwide study results showed that the presences of high-risk HPV DNA were detected in 99.7% of cervical cancer patients. Therefore, the early detection and prevention of cervical HPV are the key to blocking canceration. The establishment of a simple, specific and rapid pathogenic diagnostic method is of great significance in the clinical diagnosis of cervical cancer.

Features

● Multiplex PCR Amplification Technology.
● Internal control: Fully monitor the experimental process to ensure the quality of Experiments.
● High specificity: No cross-reactivity with common respiratory pathogens for more accurate results.
● High sensitivity: 25 copies/reaction.
● Convenient: One test for multiple results.

Channel

FAM HPV 18
VIC (HEX) HPV 16
ROX HPV 26, 31, 33, 35, 39, 45, 51, 52, 53, 56, 58, 59, 66, 68, 73, 82
CY5 Internal control

PCR Amplification Conditions Setting

Step Cycles Temperature Time Collect Fluorescent Signals or Not
1 1 cycle 50℃ 2 mins No
2 1 cycle 95℃ 10 mins No
3 10 cycle 95℃ 15 s No
62℃ 20 s No
4 30 cycle 95℃ 15 s No
58℃ 30 s Yes

Technical Parameters

Storage ≤-18℃ in dark
Shelf-life 24 months
Specimen Type Cervical exfoliated cells
Ct ≤28
CV ≤5.0%
LoD 25 Copies/reaction
Specificity No cross-reactivity with common reproductive tract pathogens (such as ureaplasma urealyticum, genital tract chlamydia trachomatis, candida albicans, neisseria gonorrhoeae, trichomonas vaginalis, mold, gardnerella and other HPV types not covered in the kit, etc).
Applicable Instruments It can match the mainstream fluorescent PCR instruments on the market.
SLAN-96P Real-Time PCR Systems
ABI 7500 Real-Time PCR Systems
QuantStudio®5 Real-Time PCR Systems
LightCycler®480 Real-Time PCR Systems
LineGene 9600 Plus Real-Time PCR Detection Systems
MA-6000 Real-Time Quantitative Thermal Cycler

Main Components

Catalogue Number Component (50 tests/kit) Specification Quantity Component Description
HWTS-CC011A 18 HPV Reaction Buffer 1.25mL/vial 1 vial Amplification reaction reagents and kinds of primers, probes
18 HPV Positive Control 600μL/vial 1 vial Mixture of HPV 16, 18, 33 and their internal control plasmids
18 HPV Blank Control 600μL/vial 1 vial DNase/RNase free H2O

Total PCR Solution

Option 1.
1. Sampling

Option

2. Nucleic acid extraction

2.Nucleic acid extraction

3. Add samples to the machine

3.Add samples to the machine

Option 2.
1. Sampling

Option

2. Extraction-free

2.Extraction-free

3. Add samples to the machine

3.Add samples to the machine`


Product detail pictures:

OEM/ODM Manufacturer Hpv 16 18 - 18 Types of High-risk Human Papilloma Virus Nucleic Acid Detection Kit – Macro & Micro-Test detail pictures


Related Product Guide:

With responsible good quality method, good status and excellent client services, the series of solutions produced by our company are exported to lots of countries and regions for OEM/ODM Manufacturer Hpv 16 18 - 18 Types of High-risk Human Papilloma Virus Nucleic Acid Detection Kit – Macro & Micro-Test , The product will supply to all over the world, such as: Eindhoven, Luxembourg, Cyprus, Since our establishment, we keep on improving our products and customer service. We are able to provide you with a wide range of high quality hair products at competitive prices. Also we can produce different hair products according to your samples. We insist on high quality and reasonable price. Except this, we provide best OEM service. We warmly welcome OEM orders and customers all over the world to cooperate with us for mutual development in the future.
  • It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
    5 Stars By Natividad from Nicaragua - 2017.05.02 18:28
    Perfect services, quality products and competitive prices, we have work many times, every time is delighted, wish continue to maintain!
    5 Stars By Fanny from Brazil - 2017.12.09 14:01
    Write your message here and send it to us