OEM/ODM Manufacturer Hpv 16 18 - 18 Types of High-risk Human Papilloma Virus Nucleic Acid Detection Kit – Macro & Micro-Test

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Always customer-oriented, and it's our ultimate goal to get not only by far the most reputable, trustable and honest supplier, but also the partner for our customers for Enterovirus 71 And Coxsackievirus A16, Adenovirus 41, Ros1 Gene Mutation Detection, Our main objectives are to deliver our consumers worldwide with high quality, competitive selling price, satisfied delivery and outstanding providers.
OEM/ODM Manufacturer Hpv 16 18 - 18 Types of High-risk Human Papilloma Virus Nucleic Acid Detection Kit – Macro & Micro-Test Detail:

Product name

18 Types of High-risk Human Papilloma Virus Nucleic Acid Detection Kit (Fluorescence PCR)

Certificate

CE

Epidemiology

Cervical cancer is one of the most common malignant tumors in the female reproductive tract. Studies have shown that persistent infection and multiple infections of human papillomavirus are one of the important causes of cervical cancer.

Reproductive tract HPV infection is common among women with sexual life. According to statistics, 70% to 80% of women may have HPV infection for once at least in their lifetime, but most infections are self-limiting, and more than 90% of infected women will develop an effective immune response that could clear the infection between 6 and 24 months without any long-term health intervention. Persistent high-risk HPV infection is the main cause of cervical intraepithelial neoplasia and cervical cancer.

The worldwide study results showed that the presences of high-risk HPV DNA were detected in 99.7% of cervical cancer patients. Therefore, the early detection and prevention of cervical HPV are the key to blocking canceration. The establishment of a simple, specific and rapid pathogenic diagnostic method is of great significance in the clinical diagnosis of cervical cancer.

Features

● Multiplex PCR Amplification Technology.
● Internal control: Fully monitor the experimental process to ensure the quality of Experiments.
● High specificity: No cross-reactivity with common respiratory pathogens for more accurate results.
● High sensitivity: 25 copies/reaction.
● Convenient: One test for multiple results.

Channel

FAM HPV 18
VIC (HEX) HPV 16
ROX HPV 26, 31, 33, 35, 39, 45, 51, 52, 53, 56, 58, 59, 66, 68, 73, 82
CY5 Internal control

PCR Amplification Conditions Setting

Step Cycles Temperature Time Collect Fluorescent Signals or Not
1 1 cycle 50℃ 2 mins No
2 1 cycle 95℃ 10 mins No
3 10 cycle 95℃ 15 s No
62℃ 20 s No
4 30 cycle 95℃ 15 s No
58℃ 30 s Yes

Technical Parameters

Storage ≤-18℃ in dark
Shelf-life 24 months
Specimen Type Cervical exfoliated cells
Ct ≤28
CV ≤5.0%
LoD 25 Copies/reaction
Specificity No cross-reactivity with common reproductive tract pathogens (such as ureaplasma urealyticum, genital tract chlamydia trachomatis, candida albicans, neisseria gonorrhoeae, trichomonas vaginalis, mold, gardnerella and other HPV types not covered in the kit, etc).
Applicable Instruments It can match the mainstream fluorescent PCR instruments on the market.
SLAN-96P Real-Time PCR Systems
ABI 7500 Real-Time PCR Systems
QuantStudio®5 Real-Time PCR Systems
LightCycler®480 Real-Time PCR Systems
LineGene 9600 Plus Real-Time PCR Detection Systems
MA-6000 Real-Time Quantitative Thermal Cycler

Main Components

Catalogue Number Component (50 tests/kit) Specification Quantity Component Description
HWTS-CC011A 18 HPV Reaction Buffer 1.25mL/vial 1 vial Amplification reaction reagents and kinds of primers, probes
18 HPV Positive Control 600μL/vial 1 vial Mixture of HPV 16, 18, 33 and their internal control plasmids
18 HPV Blank Control 600μL/vial 1 vial DNase/RNase free H2O

Total PCR Solution

Option 1.
1. Sampling

Option

2. Nucleic acid extraction

2.Nucleic acid extraction

3. Add samples to the machine

3.Add samples to the machine

Option 2.
1. Sampling

Option

2. Extraction-free

2.Extraction-free

3. Add samples to the machine

3.Add samples to the machine`


Product detail pictures:

OEM/ODM Manufacturer Hpv 16 18 - 18 Types of High-risk Human Papilloma Virus Nucleic Acid Detection Kit – Macro & Micro-Test detail pictures


Related Product Guide:

abide by the contract, conforms into the market requirement, joins in the market competition by its good quality also as provides a lot more comprehensive and great company for purchasers to let them turn into huge winner. The pursue from the firm, would be the clients' gratification for OEM/ODM Manufacturer Hpv 16 18 - 18 Types of High-risk Human Papilloma Virus Nucleic Acid Detection Kit – Macro & Micro-Test , The product will supply to all over the world, such as: Angola, Jersey, Czech republic, Our production have been exported to more than 30 countries and regions as first hand source with lowest price. We sincerely welcome customers from both at home and abroad to come to negotiate business with us.
  • Factory equipment is advanced in the industry and the product is fine workmanship, moreover the price is very cheap, value for money!
    5 Stars By Olga from Czech republic - 2018.12.14 15:26
    We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
    5 Stars By Clara from Poland - 2017.08.21 14:13
    Write your message here and send it to us