OEM China Hpv Cervix - 28 Types of HPV Nucleic Acid Detection Kit (Fluorescence PCR ) – Macro & Micro-Test

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Sincerity, Innovation, Rigorousness, and Efficiency could be the persistent conception of our enterprise to the long-term to produce together with clients for mutual reciprocity and mutual profit for Human Chorionic Gonadotropin Detection Kit, Tuberculosis Pcr, Denv-1 To 4, We welcome clients, enterprise associations and friends from all components from the earth to make contact with us and find cooperation for mutual positive aspects.
OEM China Hpv Cervix - 28 Types of HPV Nucleic Acid Detection Kit (Fluorescence PCR ) – Macro & Micro-Test Detail:

Product name

28 Types of HPV Nucleic Acid Detection Kit (Fluorescence PCR )

Certificate

CE

Epidemiology

Cervical cancer is one of the most common malignant tumors in the female reproductive tract. The studies have shown that persistent infection and multiple infections of human papillomavirus is one of the important cause of cervical cancer. At present, there is still a lack of recognized effective treatment methods for HPV. Therefore, early detection and early prevention of cervical HPV is the key to blocking canceration. The establishment of a simple, specific and rapid pathogenic diagnostic method is of great significance in the clinical diagnosis of cervical cancer.

Features

● Multiplex PCR Amplification Technology.
● Internal control: Fully monitor the experimental process to ensure the quality of Experiments.
● High sensitivity: 25 Copies/reaction
● High specificity: No cross-reactivity with common respiratory pathogens for more accurate results.
● Convenient: One test for multiple results.

Channel

S/N Channel Type
PCR-Mix1 FAM 16, 18, 31, 56
VIC(HEX) Internal Control
CY5 45, 51, 52, 53
ROX 33, 35, 58, 66
PCR-Mix2 FAM 6, 11, 54, 83
VIC(HEX) 26, 44, 61, 81
CY5 40, 42, 43, 82
ROX 39, 59, 68, 73

PCR Amplification Conditions Setting

Step Cycles Temperature Time Collect Fluorescent Signals or Not
1 1 cycle 50℃ 2 mins No
2 1 cycle 95℃ 10 mins No
3 10 cycle 95℃ 15 s No
62℃ 20 s No
4 30 cycle 95℃ 15 s No
58℃ 30 s Yes

Technical Parameters

Storage ≤-18℃ in dark
Shelf-life 12 months
Specimen Type Cervical exfoliated cells
Ct ≤28
CV ≤5.0%
LoD 25 Copies/reaction
Specificity No cross-reactivity with common reproductive tract pathogens (such as ureaplasma urealyticum, genital tract chlamydia trachomatis, candida albicans, neisseria gonorrhoeae, trichomonas vaginalis, mold, gardnerella and other HPV types not covered in the kit, etc).
Applicable Instruments It can match the mainstream fluorescent PCR instruments on the market.
SLAN-96P Real-Time PCR Systems
ABI 7500 Real-Time PCR Systems
QuantStudio®5 Real-Time PCR Systems
LightCycler®480 Real-Time PCR Systems
LineGene 9600 Plus Real-Time PCR Detection Systems
MA-6000 Real-Time Quantitative Thermal Cycler

Main Components

Catalogue Number Component (50 tests/kit) Specification Quantity Component Description
HWTS-CC003A HPV WELL1 1.3mL/vial 1 vial Mixture of specific primers and probes of HPV16, 18, 31, 33, 35, 45, 51, 52, 53, 56, 58, 66
HPV WELL2 1.3mL/vial 1 vial Mixture of specific primers and probes of HPV6, 11, 26, 39, 40, 42, 43, 44, 54, 59, 61, 68, 73, 81, 82, 83
HPV Enzyme Mix 55uL/vial 1 vial Mixture of Taq DNA polymerase, Uracil-DNA Glycosylase and glycerin
HPV Positive Control WELL1 150μL/vial 1 vial Mixture of HPV16, 18, 31, 33, 35, 45, 51, 52, 53, 56, 58, 66 templates and Internal Control template
HPV Positive Control WELL2 150μL/vial 1 vial Mixture of 6, 11, 26, 39, 40, 42, 43, 44, 54, 59, 61, 68, 73, 81, 82, 83 templates
HPV Blank Control 300μL/vial 1 vial RNase/DNase free H2O

Total PCR Solution

Option 1.

Fluorescence PCR3

Option 2.

Fluorescence PCR4


Product detail pictures:

OEM China Hpv Cervix - 28 Types of HPV Nucleic Acid Detection Kit (Fluorescence PCR ) – Macro & Micro-Test detail pictures

OEM China Hpv Cervix - 28 Types of HPV Nucleic Acid Detection Kit (Fluorescence PCR ) – Macro & Micro-Test detail pictures

OEM China Hpv Cervix - 28 Types of HPV Nucleic Acid Detection Kit (Fluorescence PCR ) – Macro & Micro-Test detail pictures

OEM China Hpv Cervix - 28 Types of HPV Nucleic Acid Detection Kit (Fluorescence PCR ) – Macro & Micro-Test detail pictures


Related Product Guide:

Our company puts emphasis on the management, the introduction of talented personnel, and the construction of staff building, trying hard to improve the quality and liability consciousness of staff members. Our company successfully attained IS9001 Certification and European CE Certification of OEM China Hpv Cervix - 28 Types of HPV Nucleic Acid Detection Kit (Fluorescence PCR ) – Macro & Micro-Test , The product will supply to all over the world, such as: Maldives, South Africa, Israel, In order to meet more market demands and long-term development, a 150, 000-square-meter new factory is under construction, which will be put into use in 2014. Then, we shall own a large capacity of producing. Of course, we will continue improving the service system to meet the requirements of customers, bringing health, happiness and beauty to everyone.
  • This is a honest and trustworthy company, technology and equipment are very advanced and the prodduct is very adequate, there is no worry in the suppliment.
    5 Stars By Elaine from Bahrain - 2017.11.11 11:41
    Sales manager is very enthusiastic and professional, gave us a great concessions and product quality is very good,thank you very much!
    5 Stars By Eden from Egypt - 2018.12.11 11:26
    Write your message here and send it to us