New Fashion Design for Monkeypox Detection Kit - Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR) – Macro & Micro-Test

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We aim to find out high quality disfigurement in the generation and provide the most effective services to domestic and abroad clients wholeheartedly for Malaria Fever, Urine Pregnancy Test Kit, 28 Types Of Hpv Nucleic Acid Detection Kit, We Sincerely welcome customers from all over the world to visit us, with our multifaceted cooperation and work together to develop new markets, create win-win brilliant future.
New Fashion Design for Monkeypox Detection Kit - Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR) – Macro & Micro-Test Detail:

Product name

Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR)
Orthopox Virus Universal Type/Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR)

Certificate

CE

Epidemiology

Monkeypox (MP) is an acute zoonotic infectious disease caused by Monkeypox Virus (MPV). The disease is mainly transmitted by animals, and humans could become infected by being bitten by infected animals or by direct contact with the blood, body fluids and rash of infected animals. The virus can also be transmitted between people, primarily through respiratory droplets during prolonged, direct face-to-face contact or through direct contact with a patient’s body fluids or contaminated objects[1-2].

The clinical symptoms of monkeypox infection in humans are similar to those of smallpox, generally after a 12-day incubation period, appearing fever, headache, muscle and back pain, enlarged lymph nodes, fatigue and discomfort. The rash appears after 1-3 days of the fever, usually first on the face, but also in other parts. The disease course generally lasts 2-4 weeks, and the mortality rate is 1%-10%. Lymphadenopathy is one of the main differences between this disease and smallpox[3].

Features

● Multiplex PCR Amplification Technology
● Accuracy: Internal control, fully monitor the experimental process to ensure the quality of Experiments.
● Rapid: Rapid PCR amplification shorts detection time, resulted in 40 minutes
● High sensitivity: 200 Copies/mL
● Triple PCR assay: Dual target gene(MPV-1 & MPV-2) of Monkeypox virus + human endogenous gene

Channel

Channel Monkeypox Monkeypox & Orthopox
FAM Monkeypox virus MPV-1 gene Orthopox virus universal type nucleic acid
VIC/HEX Monkeypox virus MPV-2 gene Monkeypox virus MPV-2 gene
ROX / Monkeypox virus MPV-1 gene
CY5 Internal Control Internal control

PCR Amplification Conditions Setting

Step Cycles Temperature Time Collect Fluorescent Signals or Not
1 1 cycle 50℃ 2mins No
2 1 cycle 95℃ 1min No
3 40 cycles 95℃ 5s No
55℃ 15s Yes

Technical Parameters

Storage ≤-18℃ in dark  
Shelf-life 2 months
Specimen Type Rash Fluid, Nasopharyngeal Swab, Throat Swab, Serum 
Ct ≤38
CV ≤5.0%
LoD 200Copies/mL
Specificity
No cross-reactivity with Smallpox virus, Cowpox virus, Vaccinia virus, Herpes simplex virus, etc. 
No cross-reactivity with other pathogens that cause rash disease. 
No cross-reactivity with human genomic DNA. 
Applicable Instruments It can match the mainstream fluorescent PCR instruments on the market.
QuantStudio®5 Real-Time PCR Systems 
SLAN-96P Real-Time PCR Systems  
LightCycler®480 Real-Time PCR Systems 
LineGene 9600 Plus Real-Time PCR Detection Systems  
MA-6000 Real-Time Quantitative Thermal Cycler  
BioRad CFX96 Real-Time PCR Systems 
BioRad CFX Opus 96 Real-Time PCR Systems 

Main Components

Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR)

Catalogue Number Component (50 tests/kit) Specification Quantity Component Description
HWTS-OT071A MPV Reaction Buffer  1.25mL /vial 1 vial Amplification reaction reagents, monkeypox virus MPV-1 and MPV-2 primer probes and internal control primer probes, etc..
MPV Positive Control  250μL/vial  1 vial Monkeypox virus and internal control mixed plasmid
MPV Blank Control 250μL/vial 1 vial DNase/RNase free H2O

Orthopox Virus Universal Type/Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR)

Catalogue Number Component (50 tests/kit) Specification Quantity Component Description
HWTS-OT072A OPV/MPV Reaction Buffer  1.25mL /vial 1 vial Amplification reaction reagents, orthopox virus universal type and monkeypox virus primer probes, internal control primer probes, etc.
OPV/MPV Positive Control  250μL/vial  1 vial Orthopox virus universal type, monkeypox virus and internal control mixed plasmid
OPV/MPV Blank Control 250μL/vial 1 vial DNase/RNase free H2O

Total PCR Solution

Option 1.

Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR)8

Option 2.

Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR)9

References

[1] Centers for Disease Control and Prevention. Human monkeypox-Kasai Oriental, Zaire, 1996-1997.MMWR. 1997, 46:304-307.
[2] Beer EM, Rao VB. A systematic review of the epidemiology of human monkeypox outbreaks and implications for outbreak strategy. PLoS Negl Trop Dis 2019 10;13(10).
[3] Jezek Z, Marennikova SS, Mutumbo M, et al. Human monkeypox: a study of 2,510 contacts of 214 patients. J Infect Dis 1986 Oct;154(4).


Product detail pictures:

New Fashion Design for Monkeypox Detection Kit - Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR) – Macro & Micro-Test detail pictures

New Fashion Design for Monkeypox Detection Kit - Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR) – Macro & Micro-Test detail pictures

New Fashion Design for Monkeypox Detection Kit - Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR) – Macro & Micro-Test detail pictures

New Fashion Design for Monkeypox Detection Kit - Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR) – Macro & Micro-Test detail pictures

New Fashion Design for Monkeypox Detection Kit - Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR) – Macro & Micro-Test detail pictures


Related Product Guide:

It can be our accountability to satisfy your preferences and competently provide you. Your satisfaction is our greatest reward. We are searching ahead towards your visit for joint growth for New Fashion Design for Monkeypox Detection Kit - Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR) – Macro & Micro-Test , The product will supply to all over the world, such as: Washington, Mombasa, Comoros, We adhere to the honest, efficient, practical win-win running mission and people-oriented business philosophy. Excellent quality, reasonable price and customer satisfaction are always pursued! If you are interested in our products, just try to contact us for more details!
  • The manufacturer gave us a big discount under the premise of ensuring the quality of products, thank you very much, we will select this company again.
    5 Stars By Delia Pesina from Netherlands - 2018.11.04 10:32
    Hope that the company could stick to the enterprise spirit of Quality, Efficiency, Innovation and Integrity, it will be better and better in the future.
    5 Stars By Daniel Coppin from Mexico - 2017.08.28 16:02
    Write your message here and send it to us