Hot-selling Ffn Test - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our mission is to become an innovative supplier of high-tech digital and communication devices by providing value added design, world-class manufacturing, and service capabilities for Denv-4, Enterovirus, Dengue Pcr Kit, Only for accomplish the good-quality product to meet customer's demand, all of our products have been strictly inspected before shipment.
Hot-selling Ffn Test - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test Detail:

Product name

Macro & Micro-Test Sample Release Reagent

Certificate

CE, FDA, NMPA

Features

Rapid: only 5 mins.

Easy: only 3 steps (1.add the sample 2.Mix upside and down 10 times 3. Leave it for 5 mins).

Main components

Name Main components Component specifications Quantity
Sample Release reagent Dithiothreitol, sodium dodecyl sulfate (SDS), RNase inhibitor, surfactant, purified water 0.5mL/Vial 50 Vial

Note: Components in different batches of kits are not interchangeable.

Storage conditions and shelf life

Store and transport at room temperature. The shelf life is 24 months. 

Applicable instruments

Instruments and equipment during sample processing, such as pipettes, vortex mixers, water baths, etc. 

Sample requirements

Freshly collected oropharyngeal swabs, nasopharyngeal swabs.

Precision

When this kit is used for extraction from the in-house precision reference CV for 10 replicates, the coefficient of variation (CV, %) of Ct value is not more than 10%.

Inter-batch difference

When the in-house precision reference is tested on three batches of kits under trial production upon repeated extraction and, the coefficient of variation (CV, %) of Ct value is not more than 10%.

Performance comparison

● Extraction efficiency comparsion

Efficiency comparsion of magnetic beads method and sample releaser

concentration
copies/mL

magnetic beads method

sample releaser

orfab

N

orfab

N

20000

28.01

28.76

28.6

29.15

2000

31.53

31.9

32.35

32.37

500

33.8

34

35.25

35.9

200

35.25

35.9

35.83

35.96

100

36.99

37.7

38.13

undet

The extraction efficiency of sample releaser was similar to that of magnetic beads method, and the concentration of pathogen could be 200Copies/mL.

● CV value comparison

Repeatability of sample releaser extraction

concentration:5000Copies/mL

ORF1ab

N

30.17

30.38

30.09

30.36

30.36

30.26

30.03

30.48

30.14

30.45

30.31

30.16

30.38

30.7

30.72

30.79

CV

0.73%

0.69%

When tested at 5,000 copies /mL, the CV of orFab and N was 0.73% and 0.69%, respectively.

Macro & Micro-Test Sample Release Reagent10


Product detail pictures:

Hot-selling Ffn Test - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test detail pictures

Hot-selling Ffn Test - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test detail pictures

Hot-selling Ffn Test - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test detail pictures

Hot-selling Ffn Test - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test detail pictures

Hot-selling Ffn Test - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test detail pictures


Related Product Guide:

Our primary objective is usually to offer our shoppers a serious and responsible small business relationship, offering personalized attention to all of them for Hot-selling Ffn Test - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test , The product will supply to all over the world, such as: Mombasa, Peru, Tunisia, Nowadays our products sell all over the domestic and abroad thanks for the regular and new customers support. We provide high quality product and competitive price, welcome the regular and new customers cooperate with us!
  • The product manager is a very hot and professional person, we have a pleasant conversation, and finally we reached a consensus agreement.
    5 Stars By Grace from Nicaragua - 2017.01.11 17:15
    The sales person is professional and responsible, warm and polite, we had a pleasant conversation and no language barriers on communication.
    5 Stars By Deborah from Gambia - 2017.02.18 15:54
    Write your message here and send it to us