Good Wholesale Vendors Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence Pcr) - Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR) – Macro & Micro-Test

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We always work as a tangible team to ensure that we can provide you with the best quality and the best price for Egfr, Eml4-Alk Fusion Testing, Ev71 Enterovirus Pcr Kit, For even more data, please do not be reluctant to call us. All inquiries from you may be highly appreciated.
Good Wholesale Vendors Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence Pcr) - Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR) – Macro & Micro-Test Detail:

Product name

Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR)
Orthopox Virus Universal Type/Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR)

Certificate

CE

Epidemiology

Monkeypox (MP) is an acute zoonotic infectious disease caused by Monkeypox Virus (MPV). The disease is mainly transmitted by animals, and humans could become infected by being bitten by infected animals or by direct contact with the blood, body fluids and rash of infected animals. The virus can also be transmitted between people, primarily through respiratory droplets during prolonged, direct face-to-face contact or through direct contact with a patient’s body fluids or contaminated objects[1-2].

The clinical symptoms of monkeypox infection in humans are similar to those of smallpox, generally after a 12-day incubation period, appearing fever, headache, muscle and back pain, enlarged lymph nodes, fatigue and discomfort. The rash appears after 1-3 days of the fever, usually first on the face, but also in other parts. The disease course generally lasts 2-4 weeks, and the mortality rate is 1%-10%. Lymphadenopathy is one of the main differences between this disease and smallpox[3].

Features

● Multiplex PCR Amplification Technology
● Accuracy: Internal control, fully monitor the experimental process to ensure the quality of Experiments.
● Rapid: Rapid PCR amplification shorts detection time, resulted in 40 minutes
● High sensitivity: 200 Copies/mL
● Triple PCR assay: Dual target gene(MPV-1 & MPV-2) of Monkeypox virus + human endogenous gene

Channel

Channel Monkeypox Monkeypox & Orthopox
FAM Monkeypox virus MPV-1 gene Orthopox virus universal type nucleic acid
VIC/HEX Monkeypox virus MPV-2 gene Monkeypox virus MPV-2 gene
ROX / Monkeypox virus MPV-1 gene
CY5 Internal Control Internal control

PCR Amplification Conditions Setting

Step Cycles Temperature Time Collect Fluorescent Signals or Not
1 1 cycle 50℃ 2mins No
2 1 cycle 95℃ 1min No
3 40 cycles 95℃ 5s No
55℃ 15s Yes

Technical Parameters

Storage ≤-18℃ in dark  
Shelf-life 2 months
Specimen Type Rash Fluid, Nasopharyngeal Swab, Throat Swab, Serum 
Ct ≤38
CV ≤5.0%
LoD 200Copies/mL
Specificity
No cross-reactivity with Smallpox virus, Cowpox virus, Vaccinia virus, Herpes simplex virus, etc. 
No cross-reactivity with other pathogens that cause rash disease. 
No cross-reactivity with human genomic DNA. 
Applicable Instruments It can match the mainstream fluorescent PCR instruments on the market.
QuantStudio®5 Real-Time PCR Systems 
SLAN-96P Real-Time PCR Systems  
LightCycler®480 Real-Time PCR Systems 
LineGene 9600 Plus Real-Time PCR Detection Systems  
MA-6000 Real-Time Quantitative Thermal Cycler  
BioRad CFX96 Real-Time PCR Systems 
BioRad CFX Opus 96 Real-Time PCR Systems 

Main Components

Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR)

Catalogue Number Component (50 tests/kit) Specification Quantity Component Description
HWTS-OT071A MPV Reaction Buffer  1.25mL /vial 1 vial Amplification reaction reagents, monkeypox virus MPV-1 and MPV-2 primer probes and internal control primer probes, etc..
MPV Positive Control  250μL/vial  1 vial Monkeypox virus and internal control mixed plasmid
MPV Blank Control 250μL/vial 1 vial DNase/RNase free H2O

Orthopox Virus Universal Type/Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR)

Catalogue Number Component (50 tests/kit) Specification Quantity Component Description
HWTS-OT072A OPV/MPV Reaction Buffer  1.25mL /vial 1 vial Amplification reaction reagents, orthopox virus universal type and monkeypox virus primer probes, internal control primer probes, etc.
OPV/MPV Positive Control  250μL/vial  1 vial Orthopox virus universal type, monkeypox virus and internal control mixed plasmid
OPV/MPV Blank Control 250μL/vial 1 vial DNase/RNase free H2O

Total PCR Solution

Option 1.

Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR)8

Option 2.

Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR)9

References

[1] Centers for Disease Control and Prevention. Human monkeypox-Kasai Oriental, Zaire, 1996-1997.MMWR. 1997, 46:304-307.
[2] Beer EM, Rao VB. A systematic review of the epidemiology of human monkeypox outbreaks and implications for outbreak strategy. PLoS Negl Trop Dis 2019 10;13(10).
[3] Jezek Z, Marennikova SS, Mutumbo M, et al. Human monkeypox: a study of 2,510 contacts of 214 patients. J Infect Dis 1986 Oct;154(4).


Product detail pictures:

Good Wholesale Vendors Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence Pcr) - Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR) – Macro & Micro-Test detail pictures

Good Wholesale Vendors Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence Pcr) - Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR) – Macro & Micro-Test detail pictures

Good Wholesale Vendors Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence Pcr) - Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR) – Macro & Micro-Test detail pictures

Good Wholesale Vendors Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence Pcr) - Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR) – Macro & Micro-Test detail pictures

Good Wholesale Vendors Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence Pcr) - Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR) – Macro & Micro-Test detail pictures


Related Product Guide:

As for competitive charges, we believe that you will be searching far and wide for anything that can beat us. We will state with absolute certainty that for such excellent at such charges we have been the lowest around for Good Wholesale Vendors Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence Pcr) - Monkeypox Virus Nucleic Acid Detection Kit (Fluorescence PCR) – Macro & Micro-Test , The product will supply to all over the world, such as: Cape Town, Greece, Bhutan, With a team of experienced and knowledgeable personnel, our market covers South America, the USA, the Mid East, and North Africa. Many customers have become our friends after good cooperation with us. If you have the requirement for any of our products, please contact us now. We are looking forward to hearing from you soon.
  • The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!
    5 Stars By Joa from Bhutan - 2018.06.09 12:42
    Adhering to the business principle of mutual benefits, we have a happy and successful transaction, we think we will be the best business partner.
    5 Stars By Joanna from belarus - 2017.11.11 11:41
    Write your message here and send it to us